Skopje

Search

Mineral insulated thermocouple sonda

Print

Description

Junction which can not be dismantled



\"Drawing 

Thermocouple (according to IEC 584 class 2).

      Couple K

 

  • 2.5°C to 330°C
  • 0.75% of 330°c to 1000°C
      Couple J

 

  • 2.5°C to 330°C
  • 0.75% of 330°c to 750°C
      Couple T

 

  • 1°C de 0°C to 130°C
  • 0.75% of 130°c to 350°C

 

Protection sheath

Nature of the sheath Couple Maximum temperature recommended according to Ø
0.5 1 1.5 2 3
Inconel 600
(1150° C max.)
K 300 500 750 750 900
J 300 300 350 350 450
Aisi 310
(1100° C max.)
K 300 300 750 750 900
Aisi 304
(800° C max.)
K - - 750 750 800
J - - 350 350 450
T - - 200 - 250

 

Junction of measure Lead connection Option
Insulated
At the earth
Extension cable 0.22 mm², metallic braid oversheath PVC (105°C) or Teflon (200°C).
  • Miniature connector with balanced pins.
  • Sliding connector.

Reviews

There are yet no reviews for this product.